Franklin Grid Distribution Transformer Monitor

POAExcluding Tax

Request a Quote

Description

Description

The Franklin Grid INCON® Distribution Transformer Monitor (DTM) provides continuous, meter-grade precision performance monitoring of high-value, mission critical, low voltage pad mount and conventional pole mount transformers.

CONTINUOUS MONITORING

The DTM continuously assesses transformer loading and thermal conditions to calculate the accumulated loss of life in real-time, updating at approximately two second intervals.

ACCELERATION FACTOR

After each interval, the DTM updates the accumulated loss of life. This considers exact interval duration and adjusts with an acceleration factor based on the loading and thermal conditions.

LIFETIME ESTIMATE

The average acceleration factor is then applied to any unmonitored time before the DTM was installed. This provides a thorough estimate of the total loss of life and can be used in predictive maintenance planning.

Specification

Components & Dimensions

DTM - Components - Wide.psd

1. IP68 weather-proof enclosure

2. Voltage leads (5)

3. Split-core Rogowski coils (4)

4. RTD temperature sensors (2)

5. Cable strain relief

6. Status indicator LED

7. Ethernet port (optional)

 

Specifications

Transformer Monitor

Applications

  • 3-Phase Wye, 100-480V Line-Neutral, 50/60 Hz
  • 3-Phase (3 and 4-wire) Delta, 480V Line-Line, 50/60 Hz
  • 3-Phase Corner-Grounded Delta, 100-480V Line-Line, 50/60 Hz

Distribution Transformer Monitoring Reporting

  • Voltage ±10%, Frequency ±5%

Power Source

  • Powered from the transformer secondary via Phase A
    and N voltage leads

 

Temperature Sensors

  • 2 each RTDs, 25lb. Magnetic-mounted, 5-foot lead length

Current Sensors

  • 4 each, Rogowski Coils, 5-foot lead length

Fuses

  • Internal fuses on phase A and neutral leads (2 Amps)

 

Environmental

Enclosure Rating

  • NEMA 4X
  • IP65 (Ethernet Option)
  • IP66/67 (Cellular Option)

Operating Temperature/Humidity

  • -40°C to +60°C / 0 – 90% RH

Storage Temperature/Humidity Range

  • -40°C to +85°C / 0 – 95% RH

Communications

Local Communication

  • Wi-Fi (TCP/IP)

User Interface

  • Embedded webserver running on Linux platform accessible via standard web browser

Protocols

  • MQTT

Embedded Device Options

  • Cat M1 Cellular

LED Indicator

  • Tri-color LED to indicate running and alarm states (can be deactivated)

Mechanical

Size (W x L x H)

  • 6.25″ x 7.75″ x 3.75″

Weight

  • 5.5 Lbs.

Mounting

  • Magnet-mount provided; Pole-mount kit available

 

Standards

  • IEC 61010 CAT IV 480V

 

Measured Parameters

Signal Channels Range Accuracy
Temperature 2 -50°C to +150°C ±3°C (1.5%)
10/12 Cycle RMS Voltage 3 90-480V RMS Lineto-
neutral
±0.5%
10/12 Cycle RMS Current 3 + Neut. 0-3000 Amps ±1%
Phase Angle 3 0° – 360° phase
difference
±2°
Line Frequency 3 47-63 Hz ±0.1 Hz
Power Factor 3 ± 1.000 ±0.05
Voltage THD 3 0% – 400% THD ±5% absolute
Current THD 3 0% – 400% THD ±5% absolute

Communication

All User Interface communication including configuration of alarms and settings, data viewing and alarm resetting can be done locally via Wi-Fi using a web browser or remotely via the cellular connection.

No Reviews Yet