Transform any basic PDU in your data center into a smart, metered PDU with our Inline Meter PDU. It ensures reliable and advanced energy measurement, providing insight into energy consumption. Let us know your requirements, and we will create the ideal Inline Meter PDU for your project at no cost, with fast delivery and attractive prices. Suitable for vertical mounting with brackets for flat surfaces or horizontal mounting as two Inline Meters side by side in a 19-inch server rack.

How it works

The operation of our Inline Meter is simple yet highly effective. Installed between the power source and the equipment to be measured, the meter calculates power consumption by measuring current and voltage. Measured values are displayed on a screen or transmitted to a monitoring system for analysis and reporting.

Benefits of our Inline Meters:

  1. Simple Transformation: Effortlessly transform a non-intelligent basic PDU into a smart, measurable PDU with the choice between vertical or half 19″ setup.
  2. Configuration Flexibility: Available in various configurations such as 1-phase 16A, 3-phase 16A, 1-phase 32A, 3-phase 32A, and 3-phase 63A, with freedom to determine cable length.
  3. Billing-Level Energy Measurement: Accurate measurement of energy consumption at billing level, including kW, kVA, V, A, and Power Factor per inlet.
  4. Powerful Remote Monitoring: Built-in SSL security and various protocols enable remote monitoring and management.
  5. Robust Processing Speed: Built-in processor with a minimum 100 MHz clock speed and 8 MB SPI Flash for optimal performance.
  6. Scalability: Up to 50 PDUs with Inline Meters can be cascaded via a single Ethernet IP address, allowing for flexible scalability.
  7. Mounting Options: Installable both vertically and horizontally, ideal for 19-inch server racks.
  8. Simple Operation: Easy installation between power source and equipment for accurate calculation of power consumption.
  9. Real-Time Monitoring: Administrators can monitor power consumption in real-time, identify inefficient equipment, and optimize configurations.
  10. Energy Usage Optimization: Obtained data assists in optimizing energy usage, reducing costs, and enhancing data center efficiency.
  11. Full Control: Transform existing basic PDUs into smart, measurable units for full control over power distribution and efficient data center management.

 

Cables & Plugs

Your Inline Meter comes with an input and output cable at the desired length specified by you. The cable, specially produced by Schleifenbauer, is LSZH-specified and ultra-flexible. An oversized diameter reduces heat generation and lowers energy consumption. In addition to the standard cable connection, a terminal connection can also be selected if desired.

Choice of cable entry location

  • Top
  • Bottom
  • Front
  • Back

Connection choice

  • Choice of connector type
  • Connector IEC320 C14 & C20 optionally available with locking
  • Terminal connection possible

 

Configurable

  • Available in colours: black, red, blue, green, orange, yellow
  • Orientation: Vertical 0U or horizontal half 19″ with 2 meters linkable to a 19″ setup
  • Optionally equipped with surge protection

Measurement

The measurements on your PDU provide insight into energy flows and enable you to manage them. You can read measurements locally or remotely via the databus. Schleifenbauer has made its bus redundant. A single cable interruption will not affect the readings or control of the PDUs; it will attempt to access via the alternative route on the ring.

View our Specifications tab below to see examples of pre configured PDU’s.  

To Learn more or enquire about this product click on the Enquire button below.

Specification

Product information Nominal electricity Phase Input Output
2DD9VNN1321 – basic PDU 32A/1-phase (24 x C13) (6 x C19) 32A 1 No metering Passive outlets Select
3E55VIM1321 – monitored PDU 32A/1-phase (24 x C13) (6 x C19) 32A 1 Metered inputs Metered outlets Select
3592VMB1322 – managed PDU 32A/1-phase (24 x C13) (6 x C19) 32A 1 Metered branches & inputs Metered & switched outlets Select
9B45VMN3366 – branch metered PDU 32A/3-phase (30 x C13) (6 x C19) 32A 3 Metered branches & inputs Passive outlets Select
4AF7VMB3366 – managed PDU 32A/3-phase (30 x C13) (6 x C19) 32A 3 Metered branches & inputs Metered & switched outlets Select
D0B9HIN3101 – metered PDU 16A/3-phase (9 x C13) 16A 3 Metered inputs Passive outlets Select
370FDIM3101 – monitored PDU 16A/3-phase (12 x C13) 16A 3 Metered inputs Metered outlets Select
D0EADIB3101 – managed PDU 16A/3-phase (12 x C13) 16A 3 Metered inputs Metered & switched outlets Select
550EHIN1321 – metered PDU 32A/1-phase (8 x C13) 32A 1 Metered inputs Passive outlets Select
9116DNN3361 – basic PDU 32A/3-phase (12 x C13) 32A 3 No metering Passive outlets Select
5F42DIS3361 – switched PDU 32A/3-phase (6 x C19) 32A 3 Metered inputs Switched outlets Select
223DVNN1101 – basic PDU 16A/1-phase (8 x C13) (1 x C19) 16A 1 No metering Passive outlets Select
E91AVIN1101 – metered PDU 16A/1-phase (18 x C13) (6 x C19) 16A 1 Metered inputs Passive outlets Select
15AFVIM1101 – monitored PDU 16A/1-phase (18 x C13) (3 x C19) 16A 1 Metered inputs Metered outlets Select
6453VIS1101 – switched PDU 16A/1-phase (22 x C13 IEC Lock) (2 x C19 IEC Lock) 16A 1 Metered inputs Switched outlets Select
0522VIB1101 – managed PDU 16A/1-phase (12 x C13) (6 x C19) 16A 1 Metered inputs Metered & switched outlets Select
B4EFVNN3101 – basic PDU 16A/3-phase (24 x C13) (6 x C19) 16A 3 No metering Passive outlets Select
1F5BVIN3101 – metered PDU 16A/3-phase (36 x C13) (6 x C19) 16A 3 Metered inputs Passive outlets Select
2B7AVIM3101 – monitored PDU 16A/3-phase (30 x C13 IEC Lock) (6 x C19 IEC Lock) 16A 3 Metered inputs Metered outlets Select
48E2VIS3101 – switched PDU 16A/3-phase (42 x C13) 16A 3 Metered inputs Switched outlets Select
7423VIB3101 – managed PDU 16A/3-phase (12 x C19) 16A 3 Metered inputs Metered & switched outlets Select
C830VNN1321 – basic PDU 32A/1-phase (2 x C19 IEC Lock) (2 x Schuko) (1 x CEE) 32A 1 No metering Passive outlets Select
E9BDVIN1321 – metered PDU 32A/1-phase (36 x C13) (6 x C19) 32A 1 Metered inputs Passive outlets Select
C285VIS1321 – switched PDU 32A/1-phase (18 x C13) (6 x C19) 32A 1 Metered inputs Switched outlets Select
9112VIB1321 – managed PDU 32A/1-phase (12 x C19) 32A 1 Metered inputs Metered & switched outlets Select
DDEBVMN1322 – branch metered PDU 32A/1-phase (18 x C13) (6 x C19) 32A 1 Metered branches & inputs Passive outlets Select
3EBEVMM1322 – monitored PDU 32A/1-phase (18 x C13) (6 x C19) 32A 1 Metered branches & inputs Metered outlets Select
78A6VMS1322 – switched PDU 32A/1-phase (24 x C13 IEC Lock) 32A 1 Metered branches & inputs Switched outlets Select
6398VNN3361 – basic PDU 32A/3-phase (30 x C13) (18 x C19) 32A 3 No metering Passive outlets Select
2B1FVIN3361 – metered PDU 32A/3-phase (36 x C13) (12 x C19) 32A 3 Metered inputs Passive outlets Select
0FAFVIM3361 – monitored PDU 32A/3-phase (18 x C13 IEC Lock) (6 x C19 IEC Lock) 32A 3 Metered inputs Metered outlets Select
86D1VIS3361 – switched PDU 32A/3-phase (24 x C13) (6 x C19) 32A 3 Metered inputs Switched outlets Select
2731VIB3361 – managed PDU 32A/3-phase (24 x C13) (12 x C19) 32A 3 Metered inputs Metered & switched outlets Select
CD52VMS3366 – switched PDU 32A/3-phase (24 x C13) (6 x C19) 32A 3 Metered branches & inputs Switched outlets Select
86DEWIB3361 – managed PDU 32A/3-phase (36 x C13 IEC Lock) (6 x C19 IEC Lock) 32A 3 Metered inputs Metered & switched outlets Select
2BDDHNN1101 – basic PDU 16A/1-phase (12 x C13 IEC Lock) 16A 1 No metering Passive outlets Select
C8CAHIN1101 – metered PDU 16A/1-phase (12 x C13) 16A 1 Metered inputs Passive outlets Select
7E95DNN1101 – basic PDU 16A/1-phase (15 x Schuko) 16A 1 No metering Passive outlets Select
1121DIN1101 – metered PDU 16A/1-phase (12 x Schuko) 16A 1 Metered inputs Passive outlets Select
2D60HIM1101 – monitored PDU 16A/1-phase (8 x C13) 16A 1 Metered inputs Metered outlets Select
45ABDIM1101 – monitored PDU 16A/1-phase (12 x C13 IEC Lock) 16A 1 Metered inputs Metered outlets Select
26A9DIS1101 – switched PDU 16A/1-phase (12 x C13 IEC Lock) 16A 1 Metered inputs Switched outlets Select
6080HIB1101 – managed PDU 16A/1-phase (6 x C13) 16A 1 Metered inputs Metered & switched outlets Select
DB12DIB1101 – managed PDU 16A/1-phase (8 x C13) (1 x Schuko) 16A 1 Metered inputs Metered & switched outlets Select
43E3HNN3101 – basic PDU 16A/3-phase (9 x C13 IEC Lock) 16A 3 No metering Passive outlets Select
D49EDIN3101 – metered PDU 16A/3-phase (9 x C13) (3 x C19) 16A 3 Metered inputs Passive outlets Select
8DA6DIS3101 – switched PDU 16A/3-phase (6 x Schuko) 16A 3 Metered inputs Switched outlets Select
5A81HNN1321 – basic PDU 32A/1-phase (12 x C13) (2 x C19) 32A 1 No metering Passive outlets Select
9F48DNN1321 – basic PDU 32A/1-phase (20 x C13) 32A 1 No metering Passive outlets Select
2C11DIN1321 – metered PDU 32A/1-phase (20 x C13) 32A 1 Metered inputs Passive outlets Select
3AA1DIM1321 – monitored PDU 32A/1-phase (16 x C13) (2 x C19) 32A 1 Metered inputs Metered outlets Select
40A2DIS1321 – switched PDU 32A/1-phase (12 x C13) 32A 1 Metered inputs Switched outlets Select
5576DIB1321 – managed PDU 32A/1-phase (12 x C13) 32A 1 Metered inputs Metered & switched outlets Select
1FB5HMN1322 – branch metered PDU 32A/1-phase (4 x C13) (2 x C19) 32A 1 Metered branches & inputs Passive outlets Select
60CADMN1322 – branch metered PDU 32A/1-phase (7 x Schuko) 32A 1 Metered branches & inputs Passive outlets Select
63F5DMM1322 – monitored PDU 32A/1-phase (16 x C13) (2 x C19) 32A 1 Metered branches & inputs Metered outlets Select
4EB5DMS1322 – switched PDU 32A/1-phase (12 x C13) 32A 1 Metered branches & inputs Switched outlets Select
D782DMB1322 – managed PDU 32A/1-phase (12 x C13) 32A 1 Metered branches & inputs Metered & switched outlets Select
66FCHNN3361 – basic PDU 32A/3-phase (6 x C19 IEC Lock) 32A 3 No metering Passive outlets Select
7496DIN3361 – metered PDU 32A/3-phase (9 x C19) 32A 3 Metered inputs Passive outlets Select
0D75DNN3361 – basic PDU 32A/3-phase (9 x C19) 32A 3 No metering Passive outlets Select
E47DDIM3361 – monitored PDU 32A/3-phase (6 x C19 IEC Lock) 32A 3 Metered inputs Metered outlets Select
728FDIB3361 – managed PDU 32A/3-phase (6 x C19 IEC Lock) 32A 3 Metered inputs Metered & switched outlets Select