Schleifenbauer Monitored PDU

POAExcluding Tax

Request a Quote

Description

Description

Our Monitored PDU ensures reliable power distribution and advanced energy metering at the individual outlet level, providing you with precise insight into your data center server rack. Say goodbye definitively to limiting standard PDUs and discover tailor-made energy management. Let us know your requirements, and we will design the perfect Monitored PDU for your project at no cost, with fast delivery. Optimize your energy management with our bespoke solution.

Cable / Cable Entry / Plugs

Your PDU comes with a custom power cable, tailored to your specifications in terms of length and plug type. Additionally, the cable connection is precisely positioned where you need it: at the top, bottom, front, or rear, seamlessly integrating into your internal infrastructure.

This cable, specially manufactured for Schleifenbauer, meets LSZH specifications and is extremely flexible. Its oversized diameter results in less heat production. In addition to the standard cable and plug connection, we also offer options such as a C20 chassis, Phoenix QPD connection, or terminal block connection, allowing you to create your own cable connection to the PDU according to your preferences.

Circuit Breaker

Discover at Schleifenbauer the freedom to customize your Power Distribution Unit by choosing your desired circuit breaker yourself. Although we use high-quality thermal circuit breaker as standard due to their quality and compact design, you are completely free to choose another fuse option that better suits your specific needs. At Schleifenbauer, we believe in customization, offer expert advice, and are ready to tailor your PDU perfectly to your requirements. Contact us today for a bespoke solution!

Surge protection

Ensuring the availability and TIER classification of your data centre is crucial. That’s why Schleifenbauer has integrated the highest quality surge protection (type 3) from Dehn into our rack PDUs, directly at your critical end equipment.

Choose to protect your data centre with Dehn surge protection and maintain the highest availability and reliability of your critical systems. Your data centre deserves the best protection, and we ensure you get it.

Casing

At Schleifenbauer, we provide custom-made aluminium enclosures for your PDU with various benefits:

  1. Outstanding Thermal Properties: Aluminium ensures excellent thermal conductivity, keeping your PDU cool during intensive usage.
  2. Weight Savings: Durable and lightweight aluminium reduces the overall weight of your PDU, which is convenient during installation and transportation.
  3. Fully Customised: We offer full customizability, allowing you to determine the length, orientation, and details of the enclosure based on your specific application.
  4. Colour Variation: Our anodized aluminium offers various colour options, allowing you to customize the appearance of your PDU to your preference or environment.
  5. ‘Custom’ Laser Engraving: Add a personal touch with ‘custom’ engraving to uniquely identify your PDU.

Outlets

With us, you can fully customise your PDU to meet your specific requirements. Whether it’s the number or type of outlets, we give you the freedom to configure your PDU exactly as you wish.

Diversity in outlets is our specialty. You have the choice of many different types.

Would you like to customize the order of the outlets to meet your specific requirements? No problem. With us, you have the flexibility to specify the order in which the outlets should be arranged to perfectly match your configuration needs.

Mounting

At Schleifenbauer, we ensure precise and secure installation of your Power Distribution Unit (PDU) in both vertical and horizontal server rack applications. Whether you require standard mounting, toolless assembly, or a custom solution, we have the expertise and resources to support you, even in situations where standard mounting is insufficient.

Rely on our highest standards of quality and safety in mounting your PDU. Contact us to discuss your requirements and discover how we can optimize the performance of your data center infrastructure.

Residual Current Measurement

At Schleifenbauer, we go beyond mere power distribution; we are committed to the safety of your electrical systems. That’s why we offer an optional Residual Current Measurement (also known as RCS or RCM module) that can be seamlessly integrated into our PDUs. With the residual current meter, you can easily locate leakage currents, even down to circuit level. This enables you to respond quickly and effectively to potential safety issues, which is crucial for protecting your equipment and ensuring business continuity.

Measurement

The measurements on your PDU provide insight into energy flows and enable you to manage them. You can read measurements locally or remotely via the databus. Schleifenbauer has made its bus redundant. A single cable interruption will not affect the readings or control of the PDUs; it will attempt to access via the alternative route on the ring.

Metering / Switching outlets

Measuring outlets: Discover the advanced capabilities of our Schleifenbauer Power Distribution Units with accurate measurement at the outlets for detailed insight into energy consumption. Energy measurement at the outlets enables you to optimize your energy management in a unique and efficient way.

Switching outlets: Thanks to the ability to remotely switch outlets, you retain control over your power infrastructure wherever you are. This goes beyond improving energy efficiency; it allows you to minimize waste and intelligently optimize resources.

Our innovative PDU solutions offer a tailored approach to energy management, enabling you to maximize system performance, particularly relevant for data centers.

Sensors

Temperature and Humidity Sensor for Intelligent Management

Enhance the functionality of your PDU by opting for optional external sensors. Schleifenbauer offers an advanced temperature and humidity sensor for intelligent monitoring. With the ability to add additional sensors, such as a water leakage sensor, via binary inputs for potential-free contact, your PDU is customized to specific needs.

All intelligent power distribution units from Schleifenbauer support the integration of our temperature and humidity sensor. This enables administrators to remotely monitor temperature and humidity levels. Setting threshold values allows administrators to identify critical levels and take proactive measures. This prevents system failures and ensures the highest level of availability for all mission-critical equipment. Make your PDU intelligent and proactive with our advanced sensor technology.

View our Specifications tab below to see examples of pre configured PDU’s.  

To Learn more or enquire about this product click on the Enquire button below.

Specification

Product information Nominal electricity Phase Input Output
2DD9VNN1321 – basic PDU 32A/1-phase (24 x C13) (6 x C19) 32A 1 No metering Passive outlets Select
3E55VIM1321 – monitored PDU 32A/1-phase (24 x C13) (6 x C19) 32A 1 Metered inputs Metered outlets Select
3592VMB1322 – managed PDU 32A/1-phase (24 x C13) (6 x C19) 32A 1 Metered branches & inputs Metered & switched outlets Select
9B45VMN3366 – branch metered PDU 32A/3-phase (30 x C13) (6 x C19) 32A 3 Metered branches & inputs Passive outlets Select
4AF7VMB3366 – managed PDU 32A/3-phase (30 x C13) (6 x C19) 32A 3 Metered branches & inputs Metered & switched outlets Select
D0B9HIN3101 – metered PDU 16A/3-phase (9 x C13) 16A 3 Metered inputs Passive outlets Select
370FDIM3101 – monitored PDU 16A/3-phase (12 x C13) 16A 3 Metered inputs Metered outlets Select
D0EADIB3101 – managed PDU 16A/3-phase (12 x C13) 16A 3 Metered inputs Metered & switched outlets Select
550EHIN1321 – metered PDU 32A/1-phase (8 x C13) 32A 1 Metered inputs Passive outlets Select
9116DNN3361 – basic PDU 32A/3-phase (12 x C13) 32A 3 No metering Passive outlets Select
5F42DIS3361 – switched PDU 32A/3-phase (6 x C19) 32A 3 Metered inputs Switched outlets Select
223DVNN1101 – basic PDU 16A/1-phase (8 x C13) (1 x C19) 16A 1 No metering Passive outlets Select
E91AVIN1101 – metered PDU 16A/1-phase (18 x C13) (6 x C19) 16A 1 Metered inputs Passive outlets Select
15AFVIM1101 – monitored PDU 16A/1-phase (18 x C13) (3 x C19) 16A 1 Metered inputs Metered outlets Select
6453VIS1101 – switched PDU 16A/1-phase (22 x C13 IEC Lock) (2 x C19 IEC Lock) 16A 1 Metered inputs Switched outlets Select
0522VIB1101 – managed PDU 16A/1-phase (12 x C13) (6 x C19) 16A 1 Metered inputs Metered & switched outlets Select
B4EFVNN3101 – basic PDU 16A/3-phase (24 x C13) (6 x C19) 16A 3 No metering Passive outlets Select
1F5BVIN3101 – metered PDU 16A/3-phase (36 x C13) (6 x C19) 16A 3 Metered inputs Passive outlets Select
2B7AVIM3101 – monitored PDU 16A/3-phase (30 x C13 IEC Lock) (6 x C19 IEC Lock) 16A 3 Metered inputs Metered outlets Select
48E2VIS3101 – switched PDU 16A/3-phase (42 x C13) 16A 3 Metered inputs Switched outlets Select
7423VIB3101 – managed PDU 16A/3-phase (12 x C19) 16A 3 Metered inputs Metered & switched outlets Select
C830VNN1321 – basic PDU 32A/1-phase (2 x C19 IEC Lock) (2 x Schuko) (1 x CEE) 32A 1 No metering Passive outlets Select
E9BDVIN1321 – metered PDU 32A/1-phase (36 x C13) (6 x C19) 32A 1 Metered inputs Passive outlets Select
C285VIS1321 – switched PDU 32A/1-phase (18 x C13) (6 x C19) 32A 1 Metered inputs Switched outlets Select
9112VIB1321 – managed PDU 32A/1-phase (12 x C19) 32A 1 Metered inputs Metered & switched outlets Select
DDEBVMN1322 – branch metered PDU 32A/1-phase (18 x C13) (6 x C19) 32A 1 Metered branches & inputs Passive outlets Select
3EBEVMM1322 – monitored PDU 32A/1-phase (18 x C13) (6 x C19) 32A 1 Metered branches & inputs Metered outlets Select
78A6VMS1322 – switched PDU 32A/1-phase (24 x C13 IEC Lock) 32A 1 Metered branches & inputs Switched outlets Select
6398VNN3361 – basic PDU 32A/3-phase (30 x C13) (18 x C19) 32A 3 No metering Passive outlets Select
2B1FVIN3361 – metered PDU 32A/3-phase (36 x C13) (12 x C19) 32A 3 Metered inputs Passive outlets Select
0FAFVIM3361 – monitored PDU 32A/3-phase (18 x C13 IEC Lock) (6 x C19 IEC Lock) 32A 3 Metered inputs Metered outlets Select
86D1VIS3361 – switched PDU 32A/3-phase (24 x C13) (6 x C19) 32A 3 Metered inputs Switched outlets Select
2731VIB3361 – managed PDU 32A/3-phase (24 x C13) (12 x C19) 32A 3 Metered inputs Metered & switched outlets Select
CD52VMS3366 – switched PDU 32A/3-phase (24 x C13) (6 x C19) 32A 3 Metered branches & inputs Switched outlets Select
86DEWIB3361 – managed PDU 32A/3-phase (36 x C13 IEC Lock) (6 x C19 IEC Lock) 32A 3 Metered inputs Metered & switched outlets Select
2BDDHNN1101 – basic PDU 16A/1-phase (12 x C13 IEC Lock) 16A 1 No metering Passive outlets Select
C8CAHIN1101 – metered PDU 16A/1-phase (12 x C13) 16A 1 Metered inputs Passive outlets Select
7E95DNN1101 – basic PDU 16A/1-phase (15 x Schuko) 16A 1 No metering Passive outlets Select
1121DIN1101 – metered PDU 16A/1-phase (12 x Schuko) 16A 1 Metered inputs Passive outlets Select
2D60HIM1101 – monitored PDU 16A/1-phase (8 x C13) 16A 1 Metered inputs Metered outlets Select
45ABDIM1101 – monitored PDU 16A/1-phase (12 x C13 IEC Lock) 16A 1 Metered inputs Metered outlets Select
26A9DIS1101 – switched PDU 16A/1-phase (12 x C13 IEC Lock) 16A 1 Metered inputs Switched outlets Select
6080HIB1101 – managed PDU 16A/1-phase (6 x C13) 16A 1 Metered inputs Metered & switched outlets Select
DB12DIB1101 – managed PDU 16A/1-phase (8 x C13) (1 x Schuko) 16A 1 Metered inputs Metered & switched outlets Select
43E3HNN3101 – basic PDU 16A/3-phase (9 x C13 IEC Lock) 16A 3 No metering Passive outlets Select
D49EDIN3101 – metered PDU 16A/3-phase (9 x C13) (3 x C19) 16A 3 Metered inputs Passive outlets Select
8DA6DIS3101 – switched PDU 16A/3-phase (6 x Schuko) 16A 3 Metered inputs Switched outlets Select
5A81HNN1321 – basic PDU 32A/1-phase (12 x C13) (2 x C19) 32A 1 No metering Passive outlets Select
9F48DNN1321 – basic PDU 32A/1-phase (20 x C13) 32A 1 No metering Passive outlets Select
2C11DIN1321 – metered PDU 32A/1-phase (20 x C13) 32A 1 Metered inputs Passive outlets Select
3AA1DIM1321 – monitored PDU 32A/1-phase (16 x C13) (2 x C19) 32A 1 Metered inputs Metered outlets Select
40A2DIS1321 – switched PDU 32A/1-phase (12 x C13) 32A 1 Metered inputs Switched outlets Select
5576DIB1321 – managed PDU 32A/1-phase (12 x C13) 32A 1 Metered inputs Metered & switched outlets Select
1FB5HMN1322 – branch metered PDU 32A/1-phase (4 x C13) (2 x C19) 32A 1 Metered branches & inputs Passive outlets Select
60CADMN1322 – branch metered PDU 32A/1-phase (7 x Schuko) 32A 1 Metered branches & inputs Passive outlets Select
63F5DMM1322 – monitored PDU 32A/1-phase (16 x C13) (2 x C19) 32A 1 Metered branches & inputs Metered outlets Select
4EB5DMS1322 – switched PDU 32A/1-phase (12 x C13) 32A 1 Metered branches & inputs Switched outlets Select
D782DMB1322 – managed PDU 32A/1-phase (12 x C13) 32A 1 Metered branches & inputs Metered & switched outlets Select
66FCHNN3361 – basic PDU 32A/3-phase (6 x C19 IEC Lock) 32A 3 No metering Passive outlets Select
7496DIN3361 – metered PDU 32A/3-phase (9 x C19) 32A 3 Metered inputs Passive outlets Select
0D75DNN3361 – basic PDU 32A/3-phase (9 x C19) 32A 3 No metering Passive outlets Select
E47DDIM3361 – monitored PDU 32A/3-phase (6 x C19 IEC Lock) 32A 3 Metered inputs Metered outlets Select
728FDIB3361 – managed PDU 32A/3-phase (6 x C19 IEC Lock) 32A 3 Metered inputs Metered & switched outlets Select

No Reviews Yet

Write a Review

Share your thoughts. Be the first to leave a review.

Be the first to review “Schleifenbauer Monitored PDU”

Your email address will not be published. Required fields are marked *